Listning ID 524016 Description
Milk from the container (1) enters the infrared heating chamber (2), then into the flow-through water cooler (3), and returns to the container. As long as the temperature of the milk in the container (1) is below the preset pasteurization temperature and the heating is on in the infrared heating chamber (1), water is not supplied to the instantaneous water cooler (3) and the milk is not cooled in it. The milk is circulated until it is heated to pasteurization temperature. Then the heating in the infrared heating chamber (2) is turned off, and water is supplied to the flow-through water cooler, and the milk that continues to circulate is cooled to the set temperature. After the milk has cooled, the pasteurizer turns off and the milk remains in the container until needed. Then it is pumped out of the container through a hose, and the pasteurizer is washed in a circulating way. Specifications: Additional information
Reviews
Customer reviews for this ad are not available. We will be very grateful if you leave first. Write to author
Related ads
© 2001-2024 Freelist - free classifieds of Ukraine in all regions of Ukraine (except temporarily occupied territories). All rights reserved. Using this website, including the supply of ad means you accept user agreement . This bulletin board has been working for 15 years on the equipment ordered on the Servers in Ukraine website. |